{ "currentVersion": 10.91, "id": 17, "name": "Secondary Underground Conductor", "type": "Feature Layer", "description": "", "geometryType": "esriGeometryPolyline", "sourceSpatialReference": { "wkid": 2153, "latestWkid": 2955 }, "copyrightText": "", "parentLayer": null, "subLayers": [], "minScale": 1500, "maxScale": 0, "drawingInfo": { "renderer": { "type": "uniqueValue", "field1": "SubtypeCD", "field2": null, "field3": null, "defaultSymbol": { "type": "esriSLS", "style": "esriSLSSolid", "color": [ 230, 230, 0, 255 ], "width": 3 }, "defaultLabel": "", "uniqueValueInfos": [ { "symbol": { "type": "esriSLS", "style": "esriSLSDash", "color": [ 78, 78, 78, 255 ], "width": 1 }, "value": "1", "label": "Single Phase Secondary Underground", "description": "" }, { "symbol": { "type": "esriSLS", "style": "esriSLSDash", "color": [ 78, 78, 78, 255 ], "width": 1.5 }, "value": "2", "label": "Three Phase Secondary Underground", "description": "" }, { "symbol": { "type": "esriSLS", "style": "esriSLSDashDot", "color": [ 52, 52, 52, 255 ], "width": 1 }, "value": "3", "label": "Underground Streetlight Conductor", "description": "" } ], "fieldDelimiter": "," }, "transparency": 0, "labelingInfo": null }, "defaultVisibility": true, "extent": { "xmin": 309474.8757999996, "ymin": 5478043.9194, "xmax": 316261.9951999998, "ymax": 5492406.1841, "spatialReference": { "wkid": 2153, "latestWkid": 2955 } }, "hasAttachments": false, "htmlPopupType": "esriServerHTMLPopupTypeAsHTMLText", "displayField": "CreationUser", "typeIdField": "SubtypeCD", "subtypeFieldName": "SubtypeCD", "subtypeField": "SubtypeCD", "defaultSubtypeCode": 3, "fields": [ { "name": "OBJECTID", "type": "esriFieldTypeOID", "alias": "OBJECTID", "domain": null }, { "name": "SubtypeCD", "type": "esriFieldTypeInteger", "alias": "Subtype", "domain": null }, { "name": "MeasuredLength", "type": "esriFieldTypeDouble", "alias": "Measured Length", "domain": { "type": "range", "name": "Measured Length", "description": "", "range": [ 0.25, 1000000000 ], "mergePolicy": "esriMPTSumValues", "splitPolicy": "esriSPTGeometryRatio" } }, { "name": "PhaseDesignation", "type": "esriFieldTypeInteger", "alias": "Phase Designation", "domain": null }, { "name": "NominalVoltage", "type": "esriFieldTypeInteger", "alias": "Nominal Voltage", "domain": null }, { "name": "OperatingVoltage", "type": "esriFieldTypeInteger", "alias": "Operating Voltage", "domain": { "type": "codedValue", "name": "Electric Line Voltage", "description": "", "codedValues": [ { "name": "600 V", "code": 70 }, { "name": "120 V", "code": 10 }, { "name": "208/120 V", "code": 20 }, { "name": "4.8 kV", "code": 150 }, { "name": "240/120 V", "code": 30 }, { "name": "7.2 kV", "code": 160 }, { "name": "240 V", "code": 35 }, { "name": "480/240 V", "code": 40 }, { "name": "277 V", "code": 45 }, { "name": "480/277 V", "code": 50 }, { "name": "347 V", "code": 52 }, { "name": "600/347 V", "code": 55 }, { "name": "480 V", "code": 60 }, { "name": "8.3 kV", "code": 200 }, { "name": "12.5 kV", "code": 210 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" } }, { "name": "ConductorType", "type": "esriFieldTypeString", "alias": "Conductor Type", "length": 5, "domain": { "type": "codedValue", "name": "Conductor Type", "description": "", "codedValues": [ { "name": "Aerial Cable", "code": "AER" }, { "name": "Duplex", "code": "DPLX" }, { "name": "Open Wire", "code": "OPN" }, { "name": "Quadraplex", "code": "QPLX" }, { "name": "Triplex", "code": "TPLX" }, { "name": "Single Condcutor", "code": "SNGL" } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" } }, { "name": "FeederID", "type": "esriFieldTypeString", "alias": "Feeder ID", "length": 20, "domain": null }, { "name": "FeederInfo", "type": "esriFieldTypeInteger", "alias": "Feeder Information", "domain": null }, { "name": "CableCount", "type": "esriFieldTypeInteger", "alias": "Cable Count", "domain": { "type": "range", "name": "Cable Count", "description": "", "range": [ 1, 6 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" } }, { "name": "InConduitIndicator", "type": "esriFieldTypeString", "alias": "In Conduit Indicator", "length": 5, "domain": { "type": "codedValue", "name": "Yes/No Indicator", "description": "", "codedValues": [ { "name": "No", "code": "N" }, { "name": "Yes", "code": "Y" } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" } }, { "name": "ServiceIndicator", "type": "esriFieldTypeString", "alias": "Service Indicator", "length": 5, "domain": null }, { "name": "GlobalID", "type": "esriFieldTypeGlobalID", "alias": "GlobalID", "length": 38, "domain": null }, { "name": "PhaseConductorMaterial", "type": "esriFieldTypeString", "alias": "Phase Conductor Material", "length": 5, "domain": { "type": "codedValue", "name": "Conductor Material - Underground", "description": "", "codedValues": [ { "name": "AAC", "code": "AAC" }, { "name": "AL", "code": "AL" }, { "name": "CU", "code": "CU" }, { "name": "Copper Weld", "code": "CUWD" }, { "name": "Hard Drawn Copper", "code": "HDCU" }, { "name": "Soft Drawn Copper", "code": "SDCU" }, { "name": "Stranded Copper", "code": "STCU" }, { "name": "Steel", "code": "STEL" } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" } }, { "name": "PhaseConductorSize", "type": "esriFieldTypeString", "alias": "Phase Conductor Size", "length": 5, "domain": { "type": "codedValue", "name": "Conductor Size", "description": "", "codedValues": [ { "name": "1/0", "code": "1/0" }, { "name": "10", "code": "10" }, { "name": "1000", "code": "1000" }, { "name": "12/2", "code": "12/2" }, { "name": "2", "code": "2" }, { "name": "2/0", "code": "2/0" }, { "name": "250", "code": "250" }, { "name": "3/0", "code": "3/0" }, { "name": "300", "code": "300" }, { "name": "336", "code": "336" }, { "name": "350", "code": "350" }, { "name": "4", "code": "4" }, { "name": "4/0", "code": "4/0" }, { "name": "4/2", "code": "4/2" }, { "name": "477", "code": "477" }, { "name": "500", "code": "500" }, { "name": "556", "code": "556" }, { "name": "6", "code": "6" }, { "name": "750", "code": "750" }, { "name": "8", "code": "8" }, { "name": "1272", "code": "1272" } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" } }, { "name": "PhaseInsulationType", "type": "esriFieldTypeString", "alias": "Phase Insulation Type", "length": 5, "domain": { "type": "codedValue", "name": "Underground Secondary Insulation Type", "description": "", "codedValues": [ { "name": "EPR", "code": "EPR" }, { "name": "PE", "code": "PE" }, { "name": "PVC", "code": "PVC" }, { "name": "XLPE", "code": "XLP" } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" } }, { "name": "NeutralConductorMaterial", "type": "esriFieldTypeString", "alias": "Neutral Conductor Material", "length": 5, "domain": { "type": "codedValue", "name": "Conductor Material - Underground", "description": "", "codedValues": [ { "name": "AAC", "code": "AAC" }, { "name": "AL", "code": "AL" }, { "name": "CU", "code": "CU" }, { "name": "Copper Weld", "code": "CUWD" }, { "name": "Hard Drawn Copper", "code": "HDCU" }, { "name": "Soft Drawn Copper", "code": "SDCU" }, { "name": "Stranded Copper", "code": "STCU" }, { "name": "Steel", "code": "STEL" } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" } }, { "name": "NeutralConductorSize", "type": "esriFieldTypeString", "alias": "Neutral Conductor Size", "length": 5, "domain": { "type": "codedValue", "name": "Conductor Size", "description": "", "codedValues": [ { "name": "1/0", "code": "1/0" }, { "name": "10", "code": "10" }, { "name": "1000", "code": "1000" }, { "name": "12/2", "code": "12/2" }, { "name": "2", "code": "2" }, { "name": "2/0", "code": "2/0" }, { "name": "250", "code": "250" }, { "name": "3/0", "code": "3/0" }, { "name": "300", "code": "300" }, { "name": "336", "code": "336" }, { "name": "350", "code": "350" }, { "name": "4", "code": "4" }, { "name": "4/0", "code": "4/0" }, { "name": "4/2", "code": "4/2" }, { "name": "477", "code": "477" }, { "name": "500", "code": "500" }, { "name": "556", "code": "556" }, { "name": "6", "code": "6" }, { "name": "750", "code": "750" }, { "name": "8", "code": "8" }, { "name": "1272", "code": "1272" } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" } }, { "name": "NeutralInsulationType", "type": "esriFieldTypeString", "alias": "Neutral Insulation Type", "length": 5, "domain": { "type": "codedValue", "name": "Underground Secondary Insulation Type", "description": "", "codedValues": [ { "name": "EPR", "code": "EPR" }, { "name": "PE", "code": "PE" }, { "name": "PVC", "code": "PVC" }, { "name": "XLPE", "code": "XLP" } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" } }, { "name": "SHAPE", "type": "esriFieldTypeGeometry", "alias": "SHAPE", "domain": null }, { "name": "InstallationDate", "type": "esriFieldTypeDate", "alias": "Installation Date", "length": 8, "domain": null } ], "geometryField": { "name": "SHAPE", "type": "esriFieldTypeGeometry", "alias": "SHAPE" }, "indexes": [ { "name": "R55_pk", "fields": "OBJECTID", "isAscending": true, "isUnique": true, "description": "" }, { "name": "UUID_55", "fields": "GlobalID", "isAscending": true, "isUnique": false, "description": "" }, { "name": "UUID_OID_55", "fields": "GlobalID,OBJECTID", "isAscending": true, "isUnique": true, "description": "" }, { "name": "S21_idx", "fields": "SHAPE", "isAscending": true, "isUnique": true, "description": "" } ], "types": [ { "domains": { "Enabled": {"type": "inherited"}, "MeasuredLength": {"type": "inherited"}, "LengthSource": {"type": "inherited"}, "ConstructionStatus": {"type": "inherited"}, "PhaseDesignation": { "type": "codedValue", "name": "Single Phase", "description": "", "codedValues": [ { "name": "A", "code": 4 }, { "name": "B", "code": 2 }, { "name": "C", "code": 1 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "NominalVoltage": { "type": "codedValue", "name": "Secondary Nominal Voltage", "description": "", "codedValues": [ { "name": "600 V", "code": 70 }, { "name": "120 V", "code": 10 }, { "name": "208/120 V", "code": 20 }, { "name": "240/120 V", "code": 30 }, { "name": "240 V", "code": 35 }, { "name": "480/240 V", "code": 40 }, { "name": "277 V", "code": 45 }, { "name": "480/277 V", "code": 50 }, { "name": "347 V", "code": 52 }, { "name": "600/347 V", "code": 55 }, { "name": "480 V", "code": 60 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "OperatingVoltage": { "type": "codedValue", "name": "Electric Line Voltage Secondary", "description": "Electric Line Voltage Secondary", "codedValues": [ { "name": "120 V", "code": 10 }, { "name": "208/120 V", "code": 20 }, { "name": "240/120 V", "code": 30 }, { "name": "240 V", "code": 35 }, { "name": "480/240 V", "code": 40 }, { "name": "277 V", "code": 45 }, { "name": "480/277 V", "code": 50 }, { "name": "347 V", "code": 52 }, { "name": "600/347 V", "code": 55 }, { "name": "480 V", "code": 60 }, { "name": "600 V", "code": 70 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDefaultValue" }, "ConductorType": {"type": "inherited"}, "BackfillMaterial": {"type": "inherited"}, "CableCount": {"type": "inherited"}, "InConduitIndicator": {"type": "inherited"}, "ServiceIndicator": { "type": "codedValue", "name": "Yes/No Indicator", "description": "", "codedValues": [ { "name": "No", "code": "N" }, { "name": "Yes", "code": "Y" } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "Owner": {"type": "inherited"}, "PhaseConductorMaterial": {"type": "inherited"}, "PhaseConductorSize": {"type": "inherited"}, "PhaseInsulationType": {"type": "inherited"}, "NeutralConductorMaterial": {"type": "inherited"}, "NeutralConductorSize": {"type": "inherited"}, "NeutralInsulationType": {"type": "inherited"} }, "id": 1, "name": "Single Phase Secondary Underground" }, { "domains": { "Enabled": {"type": "inherited"}, "MeasuredLength": {"type": "inherited"}, "LengthSource": {"type": "inherited"}, "ConstructionStatus": {"type": "inherited"}, "PhaseDesignation": { "type": "codedValue", "name": "Three Phase", "description": "", "codedValues": [ { "name": "ABC", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "NominalVoltage": { "type": "codedValue", "name": "Secondary Nominal Voltage", "description": "", "codedValues": [ { "name": "600 V", "code": 70 }, { "name": "120 V", "code": 10 }, { "name": "208/120 V", "code": 20 }, { "name": "240/120 V", "code": 30 }, { "name": "240 V", "code": 35 }, { "name": "480/240 V", "code": 40 }, { "name": "277 V", "code": 45 }, { "name": "480/277 V", "code": 50 }, { "name": "347 V", "code": 52 }, { "name": "600/347 V", "code": 55 }, { "name": "480 V", "code": 60 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "OperatingVoltage": { "type": "codedValue", "name": "Electric Line Voltage Secondary", "description": "Electric Line Voltage Secondary", "codedValues": [ { "name": "120 V", "code": 10 }, { "name": "208/120 V", "code": 20 }, { "name": "240/120 V", "code": 30 }, { "name": "240 V", "code": 35 }, { "name": "480/240 V", "code": 40 }, { "name": "277 V", "code": 45 }, { "name": "480/277 V", "code": 50 }, { "name": "347 V", "code": 52 }, { "name": "600/347 V", "code": 55 }, { "name": "480 V", "code": 60 }, { "name": "600 V", "code": 70 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDefaultValue" }, "ConductorType": {"type": "inherited"}, "BackfillMaterial": {"type": "inherited"}, "CableCount": {"type": "inherited"}, "InConduitIndicator": {"type": "inherited"}, "ServiceIndicator": { "type": "codedValue", "name": "Yes/No Indicator", "description": "", "codedValues": [ { "name": "No", "code": "N" }, { "name": "Yes", "code": "Y" } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "Owner": {"type": "inherited"}, "PhaseConductorMaterial": {"type": "inherited"}, "PhaseConductorSize": {"type": "inherited"}, "PhaseInsulationType": {"type": "inherited"}, "NeutralConductorMaterial": {"type": "inherited"}, "NeutralConductorSize": {"type": "inherited"}, "NeutralInsulationType": {"type": "inherited"} }, "id": 2, "name": "Three Phase Secondary Underground" }, { "domains": { "Enabled": {"type": "inherited"}, "MeasuredLength": {"type": "inherited"}, "LengthSource": {"type": "inherited"}, "ConstructionStatus": {"type": "inherited"}, "PhaseDesignation": { "type": "codedValue", "name": "Single Phase", "description": "", "codedValues": [ { "name": "A", "code": 4 }, { "name": "B", "code": 2 }, { "name": "C", "code": 1 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "NominalVoltage": { "type": "codedValue", "name": "Secondary Nominal Voltage", "description": "", "codedValues": [ { "name": "600 V", "code": 70 }, { "name": "120 V", "code": 10 }, { "name": "208/120 V", "code": 20 }, { "name": "240/120 V", "code": 30 }, { "name": "240 V", "code": 35 }, { "name": "480/240 V", "code": 40 }, { "name": "277 V", "code": 45 }, { "name": "480/277 V", "code": 50 }, { "name": "347 V", "code": 52 }, { "name": "600/347 V", "code": 55 }, { "name": "480 V", "code": 60 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "OperatingVoltage": { "type": "codedValue", "name": "Electric Line Voltage Secondary", "description": "Electric Line Voltage Secondary", "codedValues": [ { "name": "120 V", "code": 10 }, { "name": "208/120 V", "code": 20 }, { "name": "240/120 V", "code": 30 }, { "name": "240 V", "code": 35 }, { "name": "480/240 V", "code": 40 }, { "name": "277 V", "code": 45 }, { "name": "480/277 V", "code": 50 }, { "name": "347 V", "code": 52 }, { "name": "600/347 V", "code": 55 }, { "name": "480 V", "code": 60 }, { "name": "600 V", "code": 70 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDefaultValue" }, "ConductorType": {"type": "inherited"}, "BackfillMaterial": {"type": "inherited"}, "CableCount": {"type": "inherited"}, "InConduitIndicator": {"type": "inherited"}, "ServiceIndicator": { "type": "codedValue", "name": "Not Applicable - String", "description": "", "codedValues": [ { "name": "Not Applicable", "code": "NA" } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "Owner": {"type": "inherited"}, "PhaseConductorMaterial": {"type": "inherited"}, "PhaseConductorSize": {"type": "inherited"}, "PhaseInsulationType": {"type": "inherited"}, "NeutralConductorMaterial": {"type": "inherited"}, "NeutralConductorSize": {"type": "inherited"}, "NeutralInsulationType": {"type": "inherited"} }, "id": 3, "name": "Underground Streetlight Conductor" } ], "subtypes": [ { "domains": { "Enabled": {"type": "inherited"}, "MeasuredLength": {"type": "inherited"}, "LengthSource": {"type": "inherited"}, "ConstructionStatus": {"type": "inherited"}, "PhaseDesignation": { "type": "codedValue", "name": "Single Phase", "description": "", "codedValues": [ { "name": "A", "code": 4 }, { "name": "B", "code": 2 }, { "name": "C", "code": 1 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "NominalVoltage": { "type": "codedValue", "name": "Secondary Nominal Voltage", "description": "", "codedValues": [ { "name": "600 V", "code": 70 }, { "name": "120 V", "code": 10 }, { "name": "208/120 V", "code": 20 }, { "name": "240/120 V", "code": 30 }, { "name": "240 V", "code": 35 }, { "name": "480/240 V", "code": 40 }, { "name": "277 V", "code": 45 }, { "name": "480/277 V", "code": 50 }, { "name": "347 V", "code": 52 }, { "name": "600/347 V", "code": 55 }, { "name": "480 V", "code": 60 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "OperatingVoltage": { "type": "codedValue", "name": "Electric Line Voltage Secondary", "description": "Electric Line Voltage Secondary", "codedValues": [ { "name": "120 V", "code": 10 }, { "name": "208/120 V", "code": 20 }, { "name": "240/120 V", "code": 30 }, { "name": "240 V", "code": 35 }, { "name": "480/240 V", "code": 40 }, { "name": "277 V", "code": 45 }, { "name": "480/277 V", "code": 50 }, { "name": "347 V", "code": 52 }, { "name": "600/347 V", "code": 55 }, { "name": "480 V", "code": 60 }, { "name": "600 V", "code": 70 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDefaultValue" }, "ConductorType": {"type": "inherited"}, "BackfillMaterial": {"type": "inherited"}, "CableCount": {"type": "inherited"}, "InConduitIndicator": {"type": "inherited"}, "ServiceIndicator": { "type": "codedValue", "name": "Yes/No Indicator", "description": "", "codedValues": [ { "name": "No", "code": "N" }, { "name": "Yes", "code": "Y" } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "Owner": {"type": "inherited"}, "PhaseConductorMaterial": {"type": "inherited"}, "PhaseConductorSize": {"type": "inherited"}, "PhaseInsulationType": {"type": "inherited"}, "NeutralConductorMaterial": {"type": "inherited"}, "NeutralConductorSize": {"type": "inherited"}, "NeutralInsulationType": {"type": "inherited"} }, "defaultValues": { "Enabled": 1, "CreationUser": null, "DateCreated": null, "LastUser": null, "DateModified": null, "SubtypeCD": 1, "MeasuredLength": null, "LengthSource": "MS", "ConstructionStatus": 5, "WorkOrderID": null, "Comments": null, "Hyperlink": null, "PhaseDesignation": null, "NominalVoltage": 30, "OperatingVoltage": 30, "ConductorType": null, "FeederID": null, "FeederID2": null, "ElectricTraceWeight": null, "FeederInfo": null, "LabelText": null, "BackfillMaterial": null, "BuriedDepth": null, "CableCount": 1, "InConduitIndicator": "Y", "ServiceIndicator": null, "GlobalID": null, "Owner": "COP", "PhaseConductorMaterial": null, "PhaseConductorSize": null, "PhaseInsulationType": null, "NeutralConductorMaterial": null, "NeutralConductorSize": null, "NeutralInsulationType": null, "InstallationDate": null }, "code": 1, "name": "Single Phase Secondary Underground" }, { "domains": { "Enabled": {"type": "inherited"}, "MeasuredLength": {"type": "inherited"}, "LengthSource": {"type": "inherited"}, "ConstructionStatus": {"type": "inherited"}, "PhaseDesignation": { "type": "codedValue", "name": "Three Phase", "description": "", "codedValues": [ { "name": "ABC", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "NominalVoltage": { "type": "codedValue", "name": "Secondary Nominal Voltage", "description": "", "codedValues": [ { "name": "600 V", "code": 70 }, { "name": "120 V", "code": 10 }, { "name": "208/120 V", "code": 20 }, { "name": "240/120 V", "code": 30 }, { "name": "240 V", "code": 35 }, { "name": "480/240 V", "code": 40 }, { "name": "277 V", "code": 45 }, { "name": "480/277 V", "code": 50 }, { "name": "347 V", "code": 52 }, { "name": "600/347 V", "code": 55 }, { "name": "480 V", "code": 60 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "OperatingVoltage": { "type": "codedValue", "name": "Electric Line Voltage Secondary", "description": "Electric Line Voltage Secondary", "codedValues": [ { "name": "120 V", "code": 10 }, { "name": "208/120 V", "code": 20 }, { "name": "240/120 V", "code": 30 }, { "name": "240 V", "code": 35 }, { "name": "480/240 V", "code": 40 }, { "name": "277 V", "code": 45 }, { "name": "480/277 V", "code": 50 }, { "name": "347 V", "code": 52 }, { "name": "600/347 V", "code": 55 }, { "name": "480 V", "code": 60 }, { "name": "600 V", "code": 70 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDefaultValue" }, "ConductorType": {"type": "inherited"}, "BackfillMaterial": {"type": "inherited"}, "CableCount": {"type": "inherited"}, "InConduitIndicator": {"type": "inherited"}, "ServiceIndicator": { "type": "codedValue", "name": "Yes/No Indicator", "description": "", "codedValues": [ { "name": "No", "code": "N" }, { "name": "Yes", "code": "Y" } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "Owner": {"type": "inherited"}, "PhaseConductorMaterial": {"type": "inherited"}, "PhaseConductorSize": {"type": "inherited"}, "PhaseInsulationType": {"type": "inherited"}, "NeutralConductorMaterial": {"type": "inherited"}, "NeutralConductorSize": {"type": "inherited"}, "NeutralInsulationType": {"type": "inherited"} }, "defaultValues": { "Enabled": 1, "CreationUser": null, "DateCreated": null, "LastUser": null, "DateModified": null, "SubtypeCD": 2, "MeasuredLength": null, "LengthSource": "MS", "ConstructionStatus": 5, "WorkOrderID": null, "Comments": null, "Hyperlink": null, "PhaseDesignation": 7, "NominalVoltage": 20, "OperatingVoltage": 20, "ConductorType": null, "FeederID": null, "FeederID2": null, "ElectricTraceWeight": null, "FeederInfo": null, "LabelText": null, "BackfillMaterial": null, "BuriedDepth": null, "CableCount": 1, "InConduitIndicator": "Y", "ServiceIndicator": null, "GlobalID": null, "Owner": "COP", "PhaseConductorMaterial": null, "PhaseConductorSize": null, "PhaseInsulationType": null, "NeutralConductorMaterial": null, "NeutralConductorSize": null, "NeutralInsulationType": null, "InstallationDate": null }, "code": 2, "name": "Three Phase Secondary Underground" }, { "domains": { "Enabled": {"type": "inherited"}, "MeasuredLength": {"type": "inherited"}, "LengthSource": {"type": "inherited"}, "ConstructionStatus": {"type": "inherited"}, "PhaseDesignation": { "type": "codedValue", "name": "Single Phase", "description": "", "codedValues": [ { "name": "A", "code": 4 }, { "name": "B", "code": 2 }, { "name": "C", "code": 1 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "NominalVoltage": { "type": "codedValue", "name": "Secondary Nominal Voltage", "description": "", "codedValues": [ { "name": "600 V", "code": 70 }, { "name": "120 V", "code": 10 }, { "name": "208/120 V", "code": 20 }, { "name": "240/120 V", "code": 30 }, { "name": "240 V", "code": 35 }, { "name": "480/240 V", "code": 40 }, { "name": "277 V", "code": 45 }, { "name": "480/277 V", "code": 50 }, { "name": "347 V", "code": 52 }, { "name": "600/347 V", "code": 55 }, { "name": "480 V", "code": 60 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "OperatingVoltage": { "type": "codedValue", "name": "Electric Line Voltage Secondary", "description": "Electric Line Voltage Secondary", "codedValues": [ { "name": "120 V", "code": 10 }, { "name": "208/120 V", "code": 20 }, { "name": "240/120 V", "code": 30 }, { "name": "240 V", "code": 35 }, { "name": "480/240 V", "code": 40 }, { "name": "277 V", "code": 45 }, { "name": "480/277 V", "code": 50 }, { "name": "347 V", "code": 52 }, { "name": "600/347 V", "code": 55 }, { "name": "480 V", "code": 60 }, { "name": "600 V", "code": 70 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDefaultValue" }, "ConductorType": {"type": "inherited"}, "BackfillMaterial": {"type": "inherited"}, "CableCount": {"type": "inherited"}, "InConduitIndicator": {"type": "inherited"}, "ServiceIndicator": { "type": "codedValue", "name": "Not Applicable - String", "description": "", "codedValues": [ { "name": "Not Applicable", "code": "NA" } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "Owner": {"type": "inherited"}, "PhaseConductorMaterial": {"type": "inherited"}, "PhaseConductorSize": {"type": "inherited"}, "PhaseInsulationType": {"type": "inherited"}, "NeutralConductorMaterial": {"type": "inherited"}, "NeutralConductorSize": {"type": "inherited"}, "NeutralInsulationType": {"type": "inherited"} }, "defaultValues": { "Enabled": 1, "CreationUser": null, "DateCreated": null, "LastUser": null, "DateModified": null, "SubtypeCD": 3, "MeasuredLength": null, "LengthSource": "MS", "ConstructionStatus": 5, "WorkOrderID": null, "Comments": null, "Hyperlink": null, "PhaseDesignation": 4, "NominalVoltage": 10, "OperatingVoltage": 10, "ConductorType": null, "FeederID": null, "FeederID2": null, "ElectricTraceWeight": null, "FeederInfo": null, "LabelText": null, "BackfillMaterial": null, "BuriedDepth": null, "CableCount": 1, "InConduitIndicator": null, "ServiceIndicator": "NA", "GlobalID": null, "Owner": "COP", "PhaseConductorMaterial": null, "PhaseConductorSize": null, "PhaseInsulationType": null, "NeutralConductorMaterial": null, "NeutralConductorSize": null, "NeutralInsulationType": null, "InstallationDate": null }, "code": 3, "name": "Underground Streetlight Conductor" } ], "relationships": [ { "id": 5, "name": "Conduit System", "relatedTableId": 28, "role": "esriRelRoleDestination", "keyField": "ULSGlobalID", "cardinality": "esriRelCardinalityManyToMany", "composite": false } ], "canModifyLayer": true, "canScaleSymbols": false, "hasLabels": false, "capabilities": "Map,Query,Data", "maxRecordCount": 1000, "supportsStatistics": true, "supportsAdvancedQueries": true, "supportedQueryFormats": "JSON, geoJSON", "isDataVersioned": true, "ownershipBasedAccessControlForFeatures": {"allowOthersToQuery": true}, "useStandardizedQueries": true, "advancedQueryCapabilities": { "useStandardizedQueries": true, "supportsStatistics": true, "supportsHavingClause": true, "supportsCountDistinct": true, "supportsOrderBy": true, "supportsDistinct": true, "supportsPagination": true, "supportsTrueCurve": true, "supportsReturningQueryExtent": true, "supportsQueryWithDistance": true, "supportsSqlExpression": true }, "supportsDatumTransformation": true, "hasGeometryProperties": true, "geometryProperties": { "shapeLengthFieldName": "SHAPE.STLength()", "units": "esriMeters" }, "dateFieldsTimeReference": null, "supportsCoordinatesQuantization": true, "serviceItemId": "81277a74cfe04125999d67e55c8aca55" }